#Ring doorbell transformer box full
Moreover, regarding temperature testing it says “Temperatures are determined during a cyclic test of 20 cycles, each cycle consisting of 1 min operation with the simulated full load and 5 min operation with a load of 20% of the simulated full load.” Therefore using a bell transformer for continuous use determines a temperature rise of the transformer which could cause it to stop supplying power, unless the work/pause cycle allows the transformer to sufficiently cool down. The reference standard EN 6 does not specify a specific time but states “Bell and chime transformers are generally intended to supply domestic sound signalling equipment and other similar devices where the load is applied for short periods of time.” How long can a bell transformer supply power? Non-inherently short-circuit proof transformer:Įquipped with a PTC protective device which reduces the current in the input circuit when the transformer is overloaded or short-circuited andĬontinues to function after fault resolution. It can be equipped with an external protective device, which reactivates after fault resolution. Permanently fails to function during overload or short-circuit presenting no danger to the user or surroundings. Website DIN rail transformers_Brochure_EN.pdf What do fail-safe transformer and non-inherently short-circuit proof transformer mean? Fail-safe transformer: Quoting from:- ABB_Modular DIN rail transformers_Brochure_EN.pdf It maybe cheaper to buy a separate din rail enclosure and transformer if you look. Yes you could replace your current bell with an exclosure. The new cable used must match the wire gauge of the existing wiring in the low down electrical box.No, those transformers need to be in an enclosure, because of the main voltage. If so it may be necessary to make a temporary hole in the drywall near the blocking so that you can drill a hole through it for the new cable. Once the new box is all installed in place you can mount the new transformer on the box cover of that new box with the low voltage wire terminals being up near the ceiling.īefore you start do check that wall cavity to see if it has a cross member or fire block that would impede pushing the cable up the cavity. Then drop a new electrical cable down the stud cavity from the new opening and enter into the existing electrical box (it may turn out to be easier to push the new cable through the existing electrical box up the wall to the new opening where you can reach in and snag the new cable). If I were doing this I would make a new opening for an old work electrical box up near the ceiling of the closet. The low voltage wires should not be inside the electrical box. The line voltage parts of the circuit must be contained inside an electrical box which has an accessible cover. I’m in Virginia and would like to do this to code. So- do I just expose the transformer at waist height and surrounded by coats, or can I put the whole mess in the wall and cover it appropriately (vented panel?). The doorbell wire runs vertically in the same wall cavity (red area) and has enough slack to reach the green area easily.
#Ring doorbell transformer box code
I know code requires this to be accessible so I can’t drywall over it, but can I have a transformer like that attached to a gang box on its side, with all of the wiring behind a cover plate? Or cover plates?Īs seen here the 120v is behind the existing wall plate in a single box currently mounted on a stud. What I’d like to do is mount the transformer in the wall cavity.


Would that be a problem if I surface-mounted the transformer? But it is waist-high and would be covered by coats all the time. The location is in a coat closet, with an existing (currently capped) 120vAC line and close proximity to the doorbell wiring.
#Ring doorbell transformer box install
I can disconnect and patch through the existing LV wiring easy enough though and I have a much more accessible location to install an updated one. My current under-powered doorbell transformer is in a very awkward location (old home, etc.) and in a location where several old wires are cable-nutted together and I would rather not replace it there.